Roof and Gutter De-icing by Self-regulating Heating Cable
RGS series are used on roofs to provide a continuous drain path for melted ice and snow to flow through the gutter and to the downspout. The self-regulating characteristic adjusts cable's heat output in accordance with the ambient condition. In snow and icy water, the heating cable operates at full power. As the snow melts and the water drains away, RGS self-regulates to half power. As it gets warmer, the power output will decrease to reduce energy consumption.
-
Features
- Temperature self-regulating, never over-heating, safe to overlap
- Can be cut to lengths and terminated in the field
- Applicable for all types of roofs and gutters
- Designed to be subject to water and sunlight
- No temperature controller is required
- Energy conservative
Cable Construction
Bus Wire: Tinned copper
Heating Core: Semi-conductive Self-limiting Matrix
Insulation: Radiation Crossed-linked Polyolefin
Braiding: Tinned copper
Outer Jacket: Thermoplastic or Fluoropolymer
Can be pre-assembled with power cord and plug for easy installation
(Model Number: ESR)Performance
Apply Voltage:110V~120V and 220V~277V
Power Output: In ice or snow at 0°C 40W/m, In air at 10°C 26W/m
Max. Maintenance Temperature: 65℃
Max. Exposure Temperature: 85℃
Min. Installation Temperature: -18℃
Min. Bending Radius(-18℃): 15mmOrdering Information
Model Number Voltage Outer Jacket RGS026ME1-0000-CR 110V~120V Thermoplastic RGS026ME1-0000-CT 110V~120V Fluoropolymer RGS026ME2-0000-CR 220V~277V Thermoplastic RGS026ME2-0000-CT 220V~277V Fluoropolymer -
Features
- Temperature self-regulating, never over-heating, safe to overlap
- Can be cut to lengths and terminated in the field
- Applicable for all types of roofs and gutters
- Designed to be subject to water and sunlight
- No temperature controller is required
- Energy conservative
view certificate
Cable Construction
Bus Wire: Tinned copper
Heating Core: Semi-conductive Self-limiting Matrix
Insulation: Radiation Crossed-linked Polyolefin
Braiding: Tinned copper
Outer Jacket: Elastomer with UV inhibitor
Can be pre-assembled with power cord and plug for easy installation
(Model Number: ESR)Performance
Apply Voltage:110V~120V and 220V~277V
Power Output: In ice or snow at 0°C 12W/ft, In air at 10°C 7.8W/ft
Max. Maintenance Temperature: 65℃
Max. Exposure Temperature: 85℃
Min. Installation Temperature: -18℃
Min. Bending Radius(-18℃): 0.6inchOrdering Information
Model Number Voltage Max. Circuit Length RGS008FT1 110V~120V 190ft RGS008FT2 220V~277V 394ft
Accessories
Self-regulating roof and gutter de-icing cable installation kit
Roof deicing cable automatic control receptacle
Self-regulating roof and gutter de-icing cable (RGS) connectionn kits